Dr. K. Zaman BNSB Eye Hospital, Mymensingh

Facility Identification

Dr.K.ZamanBNSBEyeHospital

 

 

 

 

 

 

 

 

Division: Dhaka

District: Mymensingh

District Code: 61

Facility Type: Non Government Hospital

Establishment Year: 1982

Type of Hospital: Eye Hospital

Category: Advanced Secondary

Size: 1.63 acres

Patient Information

The hospital provides ophthalmic management, curative and awareness building services.

Average number of patients per day: 500 (App.)

Patient number in last year: 1,12,000 (App.)

Equipments and Instruments

Cornea

Equipments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
A Slit Lamp   yes   yes      
B Corneal topography unit   yes      
C Aberrometry assessment unit     yes        
D Specular microscope     yes        
E Light microscope   yes   yes      
F Basic microbiology instruments   yes   yes      
G LASIK (Optional)     yes        

 

Glaucoma

Equipments and Instruments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
A Slit Lamp   yes   yes      
B Goldmann Applanation tonometry   yes   yes      
C Diagnostic lenses (90 D, 20D, 78D)   yes   yes      
D Gonioscope   yes   yes      
E Perkins tonometer   yes   yes      
F Pachymetry   yes   yes      
G Humphrey Visual Field Analyzer   yes   yes      
H Heidelberg retinal tomography (HRT)- shared   yes      
I Optical coherence tomography (OCT)-shared     yes        
J Anterior segment OCT     yes      
K Ultrasound biomicroscope-shared   yes   yes      
L YAG Laser for glaucoma surgery-shared   yes   yes      
M Fundus photography-shared   yes   yes      

 

Low Vision Clinic

Equipments and Instruments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
A Optical Aids for distance
a Telescopes 3x,4x,6x   yes   yes      
B Optical Aids of near spectacle magnifiers
a Prismosphere +5.0D, +8.0D, +10.0D   yes   yes      
b High spherical glasses +16.0D, +18.0D, +24.0D   yes   yes      
c Hand Magnifiers: Illuminated   yes   yes      
d Hand Magnifiers: Non Illuminated   yes   yes      
e Stand Magnifiers: Illuminated   yes   yes      
f Stand Magnifiers: Non Illuminated   yes   yes      
C Non Optical Aids
a Typoscopes   yes   yes      
b Bold Tip Black Pens   yes   yes      
c Table Light   yes   yes      
d CCTV   yes   yes      
e Telescopes 3x,4x,6x   yes   yes      

Pediatric Ophthalmology

Equipments and instruments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
A Outpatient Area
a Sheridan Gardiner test/ Cambridge simple crowding test   yes   yes      
b Simple Snellen Visual acuity charts- drum   yes   yes      
c Cardiff Card   yes          
d Set of trial lenses with trial frame   yes   yes      
e Streak retinoscope   yes   yes      
f Direct ophthalmoscope   yes   yes      
g Head-band loupe   yes   yes      
h Slit lamp with table & applanation tonometer   yes   yes      
i 90 D or 78 D lens   yes   yes      
j Ishihara color vision book   yes   yes      
k Indirect ophthalmoscope  with +20D /+30D lens, pediatric indentor and teaching mirrors   yes   yes      
l Fixation toy device   yes   yes      
m Romanes Occluder   yes yes      
n Air Puff Tonometer   yes yes      
o Tonopen     yes        
p Worth 4 dot test set with Red and Green glasses – Near vision   yes yes      
q Worth 4 dot test set with Red and Green glasses – distance vision   yes yes      
r TNO stereo test set with Red and Green glasses.   yes yes      
s Electric Hess screen with fosters torches   yes yes      
t Loose prism set   yes yes      
u Prism bar – horizontal   yes   yes      
v Prism bar – vertical   yes   yes      
w RAF ruler   yes yes      
x Synoptophore     yes        
y B-Scan   yes   yes      
z A-scan   yes   yes      
aa IOL Master Biometry   yes   yes      
  Operating Room  
Bb Probing set yes   yes      
Cc Instruments for examination Under GA yes   yes      
Dd Ptosis surgical instrument  set yes   yes      
Ee Enucleation surgical instrument set yes   yes      
Ff Chalazion surgical instrument set yes   yes      
Gg Strabismus surgical instrument set yes   yes      
Hh Cataract/Phaco surgical instrument Set yes   yes      
ii Vertical/Horizontal autoclave with Time/Pressure/Temperature indicator yes   yes      
Jj Flash/Speed autoclave/Hot air woven yes   yes      
kk Wet field cautery yes   yes      
ll HEPA Filters/ Laminar Air Flow yes   yes      
Mm Operating Microscope with continuous zoom, observer scope/CCTV yes   yes      
nn Phaco machine with in-built vitrectomy probe yes   yes      
oo Vitrectomy unit yes   yes      
B Anesthetic Equipments
A Anesthesia Unit yes   yes      
B Patient monitor with pulse oximetry, blood pressure measurements, ECG, Temperature, capnography suitable for age range of children yes   yes      
C Pediatric ventilator yes   yes      
D Defibrillator yes   yes      
E Laryngeal Mask Airway (LMA) yes   yes      
f Suction Machine              
C Optical Workshop Equipment
a Automatic lensometer yes     yes      
b Edging machine yes   yes      
c Surfacing Machine yes   yes      

 

Retina

Equipments and Instruments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
a Slit lamps   yes   yes      
b Indirect ophthalmoscopes   yes   yes      
c Lens 90D   yes   yes      
d Lens 20D   yes   yes      
e Three mirror lens   yes   yes      
f Applanation tonometer   yes   yes      
g Noncontact tonometer   yes   yes      
h Fundus camera   yes   yes      
i OCT   yes      
j Ultrasonography   yes   yes      
k Vitrectomy unit   yes   yes      
l Operating microscope   yes   yes      
m BIOM   yes   yes      
n  Boyle’s apparatus   yes   yes      
o Suction apparatus   yes   yes      
p ERG (optional)   yes   yes      

 

Adult Cataract

Equipments and Instruments

Sl No

Equipments

Available

Functioning

Total Number

Available and observed Available but not observed Not Available Yes No Don’t Know
A OPD
a Slit Lamp yes     yes      
b Schiotz Tonometer yes     yes      
c  Direct Ophthalmoscope yes   yes      
d  Indirect Ophthalmoscope yes   yes      
e 90 D lens yes   yes      
f 20 D lens yes   yes      
g Gonioprism yes     yes      
h Applanation tonometer yes     yes      
  Refraction
j Snellen test type yes   yes      
k Near vision testing yes   yes      
l Streak Retinoscope yes   yes      
m Trial frame and trial case yes   yes      
n Prism bar yes   yes      
o Refractometer yes   yes      
p A-Scan yes   yes      
q Keratometer yes   yes      
B OT
a Operating Microscope with co-axial illumination & focus control yes   yes      
b PHACO Machine yes   yes      
c Automated Vitrectomy yes   yes      
d Bipolar Cautery yes     yes      
e Steam Autoclave yes   yes      
f Flash/Speed Autoclave yes   yes      
g Suction Machine yes   yes      

Human Resources

Total human resources: 68

Senior Ophthalmologist: 7

Junior Ophthalmologist: 5

Refractionist: 10

Outpatient Nurse: 7

Ward Nurse: 4

Theatre Nurse: 5

Professional Degree: Diploma of the College of Optics, MS

Professional Training: Pediatric Ophthalmology, PHACO Surgery

Training Got from: CIETC, Arvind Eye Hospital, Japan

Cornea

1. Cornea Consultant: 1
2. Cornea Fellow: 3
3. MLOP: 4
4. 4 vision assessors work for the whole hospital.

Glaucoma

1. Ophthalmologist: 1
2. Paramedical Staff: 2

Low Vision Clinic

1. Ophthalmologist: 1
2. Optometrist: 1
3. Vocational Trainer: 1
4. Child support officer: 1

Pediatric Ophthalmology

1. Pediatric Ophthalmologist: 1
2. Fellow: 1
3. Orthoptist: 2
4. OPD Nurse: 2
5. Counselor: 2
6. Ward Nurse: 3
7. Anesthetic Assistant: 1
8. OT Nurse: 3
9. Technician: 3

Retina

1. Retina Consultant: 1
2. Fellow: 1
3. MLOP: 2
4. FFA/OCT Technician: 2

Adult Cataract

1. Senior Ophthalmologist: 5
2. Junior Ophthalmologist: 2
3. Outpatient Nurse: 3
4. Ward Nurse: 4
5. Theatre Nurse: 3

Record keeping system: Both in papers and computers.

Service Area

1. Retina

2. Glaucoma

3. Cornea

4. Surgical Cataract

5. Pediatric

Other Activities

1. Biomedical Engineering department

2. Microbiology

3. Pathology and Clinical Biochemistry

4. Housekeeping services and Dietary services

5. Opticals and Medicals

Patient Type:

Ratio of the new and old patients is 60:40. Patients from catchment area, neighboring area and far area come here for taking the treatment.

Systems and Procedures:

1. Clinical protocol and Guidelines

2. Clinical Audit

3. HMIS

4. Counseling Section

5. Procurement Policy

6. HR Policy

7. Color coded waste management