Ahsania Eye Hospital
|Facility Identification
Division: Khulna
District: Satkhira
District Code: 87
Facility Type: Private Hospital, A project of Ahsania Mission
Establishment Year: 1991
Type of Hospital: Eye Hospital
Category: Secondary level Hospital
Size of the Hospital: 1 Bigha
Funding: Ahsania Mission mainly fund this project
Patient Information
Patient Type: All types of patients from different ages visit the hospital.
Average number of patients per day: 120
Patient number in last year: 38000
Payment Provided by: Patients. Sometimes Ahsania Mission bears cost in special cases
Equipments and Instruments
They gets their equipments and instruments from BNSB Eye Hospital.
Sl No | Equipments | Available | Functioning | Total Number | ||||
Available and observed | Available but not observed | Not Available | Yes | No | Don’t Know | |||
A | OPD | |||||||
a | Slit Lamp | Yes | Yes | 1 | ||||
b | Schiotz Tonometer | Yes | Yes | 1 | ||||
c | Direct Opthalmoscope | Yes | Yes | 1 | ||||
d | Indirect Opthalmoscope | Yes | Yes | 1 | ||||
e | 90 D lens | Yes | ||||||
f | 20 D lens | Yes | ||||||
g | Gonioprism | Yes | ||||||
h | Bjerum’s screen | Yes | ||||||
i | Hess chart screen | Yes | Yes | 1 | ||||
j | Material for diplopia chart | Yes | ||||||
k | Red green goggles | Yes | ||||||
Refraction | ||||||||
m | Snellen test type | Yes | Yes | 1 | ||||
n | Near vision testing(Jaeger or Snellen) | Yes | ||||||
o | Streak Retinoscope | Yes | Yes | 1 | ||||
p | Trial Frame and trial case | Yes | Yes | 2 | ||||
q | Prism bar | Yes | ||||||
r | Refractometer | Yes | ||||||
s | A-scan | Yes | ||||||
t | Keratometer | Yes | ||||||
B | Advancer secondary eye care | |||||||
a | FFA including Fundus camera | Yes | ||||||
b | YAG Laser with slit lamp adapter | Yes | Yes | 1 | ||||
c | Laser unit for retinal coagulation | Yes | ||||||
d | Exophthalmometer | Yes | ||||||
e | B-Scan | Yes | ||||||
C | OT | |||||||
a | Operating Microscope with co-axial illumination & focus control | Yes | ||||||
b | PHACO Machine | Yes | ||||||
c | Automated Vitrectomy | Yes | ||||||
d | Bipolar Cautery | Yes | ||||||
e | Steam Autoclave | Yes | ||||||
f | Flash/Speed Autoclave | Yes | ||||||
g | Suction Machine | Yes | ||||||
h | Oxygen Cylinder with nasal canula | Yes | ||||||
i | Endotracheal intubation | Yes | ||||||
j | Ambu bag | Yes | ||||||
k | Laryngoscope | Yes | ||||||
l | BP Machine | Yes | Yes | 1 | ||||
m | Stethoscope | Yes | Yes | 1 | ||||
Surgical Instruments | ||||||||
o | Cataract surgical sets | Yes | ||||||
p | DCR set | Yes | ||||||
q | Chalazion I/C set | Yes | ||||||
r | Enucleation and Evisceration set | Yes | ||||||
D | Optical dispensing instruments | |||||||
a | Manual Edging set | Yes | ||||||
b | Rimless & Supraframes grooving machine | Yes | ||||||
c | Lensometer | Yes | ||||||
d | Trial set (Manual power check) | Yes | Yes | 1 |
Human Resources
Total Human Resources: 11
Senior Ophthalmologist: 1
Junior Ophthalmologist: 1
Refractionist: 1
Name of the Ophthalmologists: 1. Dr. Habibur Rahman
- Dr. Mofizur Rahman
Professional Degree: Diploma in Ophthalmology , FCPS
Professional Training: They got their professional training from BNSB Eye Hospital, Khulna
Administrative Human Resources:
Administrator: 1
Eye Camp Coordinator: 4
House Keeper: 1
Cleaner: 1
Security Staff: 1
Record keeping System: in papers.
Service Area
Provided Services:
- Refractive Error
- Cataract
- Glaucoma
Referral System: They refer their patients to the District hospital and BNSB Eye Hospital, Khulna. Especially for the surgical strabismus, disorder of Retina and Vitreous they mainly refer patients to those hospitals. But they do not do anything to send the patients to the referred organizations.
They only provide outdoor services. For the better service and surgery they refer their patients to the BNSB Eye Hospital, Khulna.
Workload Estimation
Number of Beds in Hospital: 00
Effective Days for providing services: 310
Surgery per year: 00
Patients per year in outdoor: 38000
Infrastructure
The size of the office is 600 sq ft. They do not have any ward or bed for patients. They do have regular electronic, gas and water supply and according to the hospital authority their hospital is clean.